ASHRAE STANDARD 55-2010 PDF

ANSI/ASHRAE Standard Thermal Environmental Conditions for Human Occupancy is an .. ANSI/ASHRAE Standard Standard references ( Appendix H) Provides a list of references in the version of the standard, with direct. ANSI/ASHRAE Standard (Supersedes ANSI/ASHRAE Standard ). Includes ANSI/ASHRAE addenda listed in Appendix |. o) ASHRAE. ANSI/ASHRAE Standard 3. It is intended that all of the criteria in this standard be applied together since comfort in the indoor environment is.

Author: Yoll Kajitaur
Country: Indonesia
Language: English (Spanish)
Genre: Relationship
Published (Last): 21 April 2008
Pages: 283
PDF File Size: 16.43 Mb
ePub File Size: 17.94 Mb
ISBN: 416-6-54834-490-6
Downloads: 90510
Price: Free* [*Free Regsitration Required]
Uploader: Barisar

Operative temperatures may not fluctuate more than 1. The methodology is based on the SET Standard Effective Temperature model, which provides a way to assign an effective temperature at a standard metabolic rate, and clothing insulation values to compare thermal sensations experienced at a range of thermal conditions.

Views Read Edit View history. In this psychrometric chart the abscissa is the dry-bulb temperature, and the mean radiant temperature MRT is fixed, controlled ashhrae the inputbox.

Thus, it only provides an approximation of the clothing insulation value of a moving person. Thermal comfort is the condition of mind that expresses satisfaction with the thermal environment and is assessed by subjective evaluation.

Section 7 underwent major revisions for measuring thermal comfort in existing spaces including procedures for physical measurements and survey methods, and how to evaluate and report results.

Documentation requirements to show that a design complies with Standard 552-010 are contained in Section 6, and a sample compliance form is provided in Appendix K. From Wikipedia, the free encyclopedia. When occupants do not have control over the cyclical variation or drifts in indoor environmental conditions, the conditions within this section must be met.

So far, all the clothing insulation value can be used when the occupant is standing. The measurement locations should be where the occupants are expected to spend time in. For such spaces, the indoor and outdoor air temperature and mean radiant temperature and the air speed need to be measured.

In the first form, different individuals wear different clothing due to factors that are not related to thermal conditions, and the second form is opposite.

The body of the standard consists of a foreword describing changes made 555-2010 the current versioneight sections and two normative appendices:. Considering that a sleeping person or one in reclining posture will be provided with sufficient insulation with the bedding material, and he or she is also free standarr adjust, it is impossible to determine the clothing insulation effect for these occupants unless they are immobile. Indoor thermal comfort can be determined from the responses of the occupant survey.

  BIOQUIMICA LEHNINGER 5TA EDICION PDF

This page was last edited on 12 Septemberat Sample documentation is provided in Informative Appendix J.

CBE Thermal Comfort Tool for ASHRAE

The second method is to add or subtract individual garment clo value to achieve the clothing ensemble in question. Clothing insulation is the resistance to sensible heat transfer provided by a clothing ensemble expressed in units of clo, which is a unit to quantify the insulation provided by garments and clothing ensembles.

For this model the standard provides a graph of acceptable indoor temperature limits at prevailing mean outdoor temperatures a mean of the daily mean 552010 temperatures of the previous 7—30 days. In the standard included the following changes. Compliance is achieved asrhae the conditions provide thermal neutrality, measured as falling asgrae Standarv standard reminds the users that they should use their own judgment to match the activities being considered to the comparable activities in the table.

When such measurement is not feasible, this standard provides four methods to determine the clothing insulation. For occupant-controlled naturally conditioned spaces, the measured results shall be check with the comfort zone established by adaptive model.

These values are valid for an average adult with surface skin area of 1.

ASHRAE 55 – Wikipedia

5-52010 measured results should be evaluated against the adjusted comfort zone for the specific building. Clothing insulation refers to the heat transfer of the entire body, which includes the uncovered parts, such as hands and heads. For seating occupants, the air temperature and air speed measurements shall be taken at heights of 0. A occupant-controlled naturally conditioned space is where the thermal conditions of the space are primarily regulated by occupant-controlled openings.

After the body of the standard there are 11 informative appendices. It was revised in,and Home Technical Resources Bookstore. For thermal comfort—this is the standard. Prevailing mean outdoor temperature. Internet Explorer is not fully supported.

  EMINEM ENCORE DIGITAL BOOKLET PDF

Standard 55 – Thermal Environmental Conditions for Human Occupancy

Set winter Set spring Set summer Set fall. In the standard was updated with more extensive information on measurement protocols and an expanded definitions section. No local air speed control With local air speed control.

We recommend using Chrome, Firefox, or Safari. For a mechanically conditioned space at an ashrea in time, the PMV and SET model shall be atandard to establish the comfort zone, and the local thermal discomfort shall be evaluated against the limit posed this standard as well.

As for point-in-time surveys, the survey should standrad solicited during the time of occupancy, and the satisfaction scale ought to be continuous. In this way you can see how changes in MRT affect thermal comfort. Retrieved from ” https: This section of the standard is applicable for the design of buildings. The stanndard addresses the four primary environmental factors temperaturethermal radiationhumidityand air speed and two personal factors activity and clothing that affect thermal comfort.

Generally, the evaluation of comfort in existing buildings can be performed from two perspectives: For occupant-controlled naturally conditioned space, the adaptive model shall be used to determine the thermal comfort boundaries.

Psychrometric chart air temperature Psychrometric chart operative temperature Temperature — Relative Humidity chart Operative Temperature — Velocity chart.

This method is based on the concept that when occupants choose their clothing according to their environment, the ashare environment is more influential than the indoor one. If these requirements are met and the environmental conditions inside the building fall within the indicated ranges, then compliance is achieved. This table can be used together with the previous one, so that one can add or subtract the clothing ensemble from the clo value of each garment.

It is defined as per unit of skin surface area which equals to In the body of the standard was rewritten in mandatory language, with informative language moved from the body of the standard to informative appendices.